Register or Log In To remove these advertisements. |
|
|
|
Thread Tools | Display Modes |
02-01-2011, 02:43 PM | #1 |
Account Suspended
Join Date: Jul 2010
Location: Southeast Texas
Posts: 189
|
dual tanks working, but right side gauge not?
hey guys, i have dual tanks on my 85 c20. they are both full, and the left side gauge works fine. but when you switch it over to the passenger side the gauge just falls down and never moves, no matter the level of gas in the tank. both tanks actually pump fuel, just the right side gauge sucks.
am i lookin at pulling the tank? heres left side-works fine passenger tank, no workie. |
02-01-2011, 02:51 PM | #2 |
Registered User
Join Date: May 2009
Location: Sparks, NV
Posts: 913
|
Re: dual tanks working, but right side gauge not?
check your wires first. trace the sending unit wire for the gauge, all the way up to the connection from the circuit board to the gauge itself.
__________________
Greg 1974 GMC 1/2 Ton SWB Fleetside L33 5.3/4l65e .................__
............._____l __\__ ..............l_(O)_ l___(O)] |
02-01-2011, 02:52 PM | #3 |
Registered User
Join Date: Sep 2009
Location: Eudora, KS
Posts: 131
|
Re: dual tanks working, but right side gauge not?
Sounds like a bad sending unit(in the tank) or a bad ground to that sending unit.
|
02-01-2011, 03:16 PM | #4 |
Registered User
Join Date: Apr 2010
Location: Newcastle, OK
Posts: 1,344
|
Re: dual tanks working, but right side gauge not?
I have found this is usually due to a bad ground on the sending unit.
Posted via Mobile Device |
02-01-2011, 04:17 PM | #5 |
Account Suspended
Join Date: Jul 2010
Location: Southeast Texas
Posts: 189
|
Re: dual tanks working, but right side gauge not?
Thanks guys. So I'm assuming sendin unit is right there stuck in the tank?
Posted via Mobile Device |
02-01-2011, 04:17 PM | #6 |
Registered User
Join Date: Dec 2009
Location: Madison, Wi
Posts: 80
|
Re: dual tanks working, but right side gauge not?
in my 1987 R30 it ended up being that the retaining clip for the float came off, and the ground was almost rubbed into 2 pieces (some how it got routed between the bed support and the frame.)
|
02-01-2011, 04:25 PM | #7 |
Registered User
Join Date: Apr 2006
Location: Huntington Beach, CA
Posts: 492
|
Re: dual tanks working, but right side gauge not?
My right side tank doesn't show on the gauge either, but rather than fall down it just keeps reading the left side. Definately not worth changing the sender, but once I "x" a few more to-dos off my list, I'm going to start tracing wires and see if it's something easy.
__________________
'87 R30 Crew Cab Dually It's 11 PM, do you know where your IAC pintle is? |
Bookmarks |
Thread Tools | |
Display Modes | |
|
|