The 1947 - Present Chevrolet & GMC Truck Message Board Network







Register or Log In To remove these advertisements.

Go Back   The 1947 - Present Chevrolet & GMC Truck Message Board Network > 47 - Current classic GM Trucks > The 1960 - 1966 Chevrolet & GMC Pickups Message Board

Web 67-72chevytrucks.com


Reply
 
Thread Tools Display Modes
Old 07-10-2014, 12:58 PM   #1
slick willie
Registered User
 
Join Date: Nov 2012
Location: San Antonio, Texas
Posts: 10
Fuel gauge issue

I'm running a stock fuel tank and installed a new sending unit.. The gauge is stuck at ¼ tank when the sending unit is installed ( the needle does not move). I removed the sending unit and grounded it to the striker plate on the door and move the float up and down …. And it works.. but when I install it will not move… I know it sounds like a ground issue but I cannot get it to work while installed regardless of where I install it. Any suggestions
slick willie is offline   Reply With Quote
Old 07-10-2014, 01:10 PM   #2
1963c-10
Registered User
 
1963c-10's Avatar
 
Join Date: Nov 2011
Location: fayetteville nc
Posts: 10,338
Re: Fuel gauge issue

1st I'd clean the mounting surface for the tank/cab grounds. Also check to make sure the floats not holding fluid....this could give you a constant 1/4 tank reading.

If the sending unit works when out of the tank and grounded to the striker plate, then I'm inclined to think the sending unit is good....just grounding issue.

Does the gauge measure properly when you grounded the sending unit to the striker plate?
__________________
1963 Short bed step side SBW 427 big block and borg warner T-16 HD 3 speed manual
http://67-72chevytrucks.com/vboard/s...d.php?t=519869
1963 Short bed fleetside BBW 348 1st gen big block w/Powerglide
http://67-72chevytrucks.com/vboard/s...d.php?t=619024
1964 Short bed trailer
1963c-10 is offline   Reply With Quote
Old 07-10-2014, 01:13 PM   #3
cortcomp
Registered User
 
cortcomp's Avatar
 
Join Date: Oct 2012
Location: cortland, oh
Posts: 792
Re: Fuel gauge issue

Do you have the ground wire from the sending unit to the inner back window panel connected? It will not ground well through the tank alone, nor should it.
__________________
Project "i'm just going to clean up the interior and the engine bay":

http://67-72chevytrucks.com/vboard/s...d.php?t=550931
cortcomp is offline   Reply With Quote
Old 07-10-2014, 01:16 PM   #4
tincan1966
Registered User
 
tincan1966's Avatar
 
Join Date: Oct 2010
Location: Independence,KS
Posts: 1,477
Re: Fuel gauge issue

It should just ground to the body, right above the tank. It is possible for the new sender to have a short in it and only be effected when installed and surrounded by fuel.

Remove the lead wire that goes from the sender to the fuel gauge(brown wire) Check for continuity from the post that wire connects to, to ground. There should be resistance. Depending on how much fuel in tank, you can estimate the ohms. 1/2 tank would be roughly 15 ohms(based on 0-33 ohm sender) If memory serves, should have less resistance at full than at empty, but I may not be correct- been a while since I checked one.
tincan1966 is offline   Reply With Quote
Old 07-10-2014, 01:17 PM   #5
cortcomp
Registered User
 
cortcomp's Avatar
 
Join Date: Oct 2012
Location: cortland, oh
Posts: 792
Re: Fuel gauge issue

Even easier, clip a jumper wire or cable from the body of the sending unit to somewhere with a good ground with it installed and see if it reads right.
__________________
Project "i'm just going to clean up the interior and the engine bay":

http://67-72chevytrucks.com/vboard/s...d.php?t=550931
cortcomp is offline   Reply With Quote
Old 07-10-2014, 02:55 PM   #6
slick willie
Registered User
 
Join Date: Nov 2012
Location: San Antonio, Texas
Posts: 10
Re: Fuel gauge issue

i do have the ground from the tank to the body installed and I did pull the float and it is not holding fluid. It looks like the quick test is for me to run a ground to the frame from the sending unit. Then test the ohms (the tank is full) so the ohms should be high close to 30? Thank you guys I'll let you know the out come.
slick willie is offline   Reply With Quote
Old 07-10-2014, 04:24 PM   #7
ol_skool_chevy
Registered User
 
ol_skool_chevy's Avatar
 
Join Date: May 2010
Location: Hillsboro, Oregon 97123
Posts: 1,300
Re: Fuel gauge issue

also be sure the float bowl is not rubbing the inside of the tank
__________________
Measure with a yard stick
Mark with Chalk
Cut with a torch



Built it yourself, don't count on others to to do it for you or with you. It will never get done
ol_skool_chevy is offline   Reply With Quote
Old 07-10-2014, 04:30 PM   #8
ACK
Registered User
 
ACK's Avatar
 
Join Date: Oct 2012
Location: Philly, PA
Posts: 540
Re: Fuel gauge issue

Just curious, have you checked the wire between the fuse box and the sending unit? Sometimes the casing rubs off and shorts out under the carpet.
__________________
My truck ain't dead, it just smells funny.
ACK is offline   Reply With Quote
Old 07-10-2014, 05:01 PM   #9
tincan1966
Registered User
 
tincan1966's Avatar
 
Join Date: Oct 2010
Location: Independence,KS
Posts: 1,477
Re: Fuel gauge issue

Quote:
Originally Posted by slick willie View Post
i do have the ground from the tank to the body installed and I did pull the float and it is not holding fluid. It looks like the quick test is for me to run a ground to the frame from the sending unit. Then test the ohms (the tank is full) so the ohms should be high close to 30? Thank you guys I'll let you know the out come.
If you can ground it to the striker bolt and it works, your problem is not the body ground, it's the ground connection between the sender and the cab when installed.

Also, the wire from the sender to the gauge must be ok, or it wouldn't work while removed and moving the float arm up and down.
tincan1966 is offline   Reply With Quote
Reply

Bookmarks

Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump


All times are GMT -4. The time now is 01:00 AM.


Powered by vBulletin® Version 3.8.11
Copyright ©2000 - 2024, vBulletin Solutions Inc.
Copyright 1997-2022 67-72chevytrucks.com