OK I'm stumped..
Ok I have an 84 2 wheel drive SWB Stepside that has been giving me hell with the fuel gauge not working... I have looked at every manual I have and and Ive seen two different wire schematics which is leaving me dumbfounded as to whats going on...I took the time to take out the cluster to inspect the printed circuit and all is well on it but I happened to notice that this cluster is out of a 4 wheel drive because light was showing through the light bulb holder hole and I saw the words 4 WHEEL DRIVE.....So can anyone on here help me figure this freaking issue out???
Keith?? anyone? |
03-07-2010, 06:13 PM | #2 |
Senior Member
Join Date: May 2009
Location: Fort Worth, TX
Posts: 6,370
|
Re: OK I'm stumped..
The dual tank option is the reason for two different wiring diagrams. So what is the gauge doing? reading empty? reading way past full?
Last edited by clinebarger; 03-07-2010 at 06:14 PM. |
03-07-2010, 06:14 PM | #3 |
Registered User
Join Date: Feb 2010
Location: Murfreesboro Tennessee
Posts: 129
|
Re: OK I'm stumped..
below empty at the moment....my truck only has a single tank though.
|
03-07-2010, 06:23 PM | #4 |
Senior Member
Join Date: May 2009
Location: Fort Worth, TX
Posts: 6,370
|
Re: OK I'm stumped..
Unplug the sender wire at the tank (pink wire). If the gauge pegs past full the float has most likley filled with fuel & has sunk to the bottem of the tank. If it stays at empty the sendor wire is shorted to ground, or the gauge is bad , or there no power at the gauge.
|
03-07-2010, 06:28 PM | #5 |
Registered User
Join Date: Feb 2010
Location: Murfreesboro Tennessee
Posts: 129
|
Re: OK I'm stumped..
See thats what makes me think the cluster isnt compatible with the truck...brand new sender and brand new gauge
|
03-07-2010, 06:34 PM | #6 |
Senior Member
Join Date: May 2009
Location: Fort Worth, TX
Posts: 6,370
|
Re: OK I'm stumped..
Im thinking the wire between the gauge and sendor is shorted to ground. Is the printed curcuit board it good shape where the plug goes? It does not make a differance if the cluster is from a 4x4.
|
03-07-2010, 06:52 PM | #7 |
Registered User
Join Date: Feb 2010
Location: Murfreesboro Tennessee
Posts: 129
|
Re: OK I'm stumped..
Yeah the printed circuit seems to be Fine.....I had my multimeter out tryin to see if I had continuity from the sender to the gauge though the wire that showed continuity was not at the pin I traced to the fuel gauge get what Im saying.
|
03-07-2010, 07:13 PM | #8 |
Senior Member
Join Date: May 2009
Location: Fort Worth, TX
Posts: 6,370
|
Re: OK I'm stumped..
Are you sure your testing the correct pin? power will be pink&black the sendor wire will be pink.
If the wire is broken somewhere it will not show continuity. But the sendor hook up on the gauge is getting grounded some how. |
03-07-2010, 08:20 PM | #9 |
Registered User
Join Date: Feb 2010
Location: Murfreesboro Tennessee
Posts: 129
|
Re: OK I'm stumped..
I found the problem....melted wires just above the fuse panel....looks like a wire harness is in order.
|
03-07-2010, 09:57 PM | #10 |
Senior Member
Join Date: May 2009
Location: Fort Worth, TX
Posts: 6,370
|
Re: OK I'm stumped..
The harness can be repaired, If wires are melted you need to find the source of the short/bad ground/component drawing to many amps.
|
03-07-2010, 10:41 PM | #11 |
Registered User
Join Date: Feb 2010
Location: Murfreesboro Tennessee
Posts: 129
|
Re: OK I'm stumped..
Thats what my uncle was just telling me....he has an 87 that I am going to get the harness from..and as far as the melted wire cause I found that problem already the wiper motor ran slow as **** even on high.
|
03-08-2010, 12:45 AM | #12 |
resident wrencher
Join Date: Dec 2006
Location: ramona california
Posts: 720
|
Re: OK I'm stumped..
hey sorry to thread jack but i have a similar problem its a 1980 c10 lwb dual tankes only feeds from the right tank and the guage on the left tank read way past full im thinking int the realy does anyone have a schematic for this set up
|
03-08-2010, 11:23 AM | #13 |
Registered User
Join Date: Oct 2009
Location: Waterboro ,MAINE
Posts: 547
|
Re: OK I'm stumped..
i have the same problem but not melted wires !!! my gauge in the truck reads empty but i discontected the PINK wire in the engine bay HOOKED it to another fuel gauge and got 12v and GROUND directly from the battery and THAT GAUGE READS over full , so maybe i thought it was the test gauge i was using and tried it again and again it read over full with the second gauge ??? what is going on with mine ????
__________________
78 C-10 5.3 LSX -4L60E |
03-08-2010, 11:44 AM | #14 |
Senior Member
Join Date: May 2009
Location: Fort Worth, TX
Posts: 6,370
|
Re: OK I'm stumped..
Here you go, I got two, there for a 82 but should be real close.
|
03-08-2010, 11:48 AM | #15 | |
Senior Member
Join Date: May 2009
Location: Fort Worth, TX
Posts: 6,370
|
Re: OK I'm stumped..
Quote:
|
|
03-08-2010, 04:56 PM | #16 |
Registered User
Join Date: Oct 2009
Location: Waterboro ,MAINE
Posts: 547
|
Re: OK I'm stumped..
yup got the right pink wire goes from the engine bay to the connector at the gas tank i disconnected the connector and got another battery i connected the battery 12v+ to the left hand stud then the GROUND to the bottom middle stud then the gauge wire that goes to the tank to the right hand stud on a spare gauge (i had 3 ) soon as i put the 12v and ground on the studs the gas gauge went straight to full, and after attaching the gauge wire had no affect on all 3 spare gauges
__________________
78 C-10 5.3 LSX -4L60E |
03-08-2010, 05:18 PM | #17 | |
Senior Member
Join Date: May 2009
Location: Fort Worth, TX
Posts: 6,370
|
Re: OK I'm stumped..
Quote:
Try grounding the other battery to the truck see what happens. When you had the harness disconnected did you see what the gauge in the truck did with the key on? The gauge pegged past full means theres a open curcuit in the sender wire, sender, or the sender is not grounded. |
|
03-08-2010, 05:49 PM | #18 | |
Registered User
Join Date: Oct 2009
Location: Waterboro ,MAINE
Posts: 547
|
Re: OK I'm stumped..
Quote:
__________________
78 C-10 5.3 LSX -4L60E |
|
03-08-2010, 06:11 PM | #19 | |
Senior Member
Join Date: May 2009
Location: Fort Worth, TX
Posts: 6,370
|
Re: OK I'm stumped..
Quote:
But to be sure, unplug the sender and your existing gauge should go past full. This will tell us the gauge is OK and the curcuit is not shorted to ground. |
|
03-08-2010, 06:15 PM | #20 |
Senior Member
Join Date: May 2009
Location: Fort Worth, TX
Posts: 6,370
|
Re: OK I'm stumped..
On a side note. Im guessing your running a inline pump? Now whould be a good time for a 87 model tank & sender with a high pressure pump in the tank.
|
03-08-2010, 07:09 PM | #21 |
Registered User
Join Date: Oct 2009
Location: Waterboro ,MAINE
Posts: 547
|
Re: OK I'm stumped..
im running a 87 sending unit with the hi psi corvette pump for my LSX i have the two wire from a 87 running from the connector at the tank up to the front, 1 wire i think its grey goes to the relay for my fuel pump the other goes to my gauge ,remember i pulled this off another 87 truck to put in my 78 ,so its got a connector in the engine bay
but you telling me to get under the truck disconnect the connector at the tank and see if it pegs out right?
__________________
78 C-10 5.3 LSX -4L60E Last edited by 78-5.3; 03-08-2010 at 07:10 PM. |
03-08-2010, 07:28 PM | #22 |
Registered User
Join Date: Feb 2010
Location: Murfreesboro Tennessee
Posts: 129
|
Re: OK I'm stumped..
thats what hes saying.
|
03-08-2010, 08:49 PM | #23 |
Registered User
Join Date: Oct 2009
Location: Waterboro ,MAINE
Posts: 547
|
Re: OK I'm stumped..
thanks for the confirmation Stepsideride
__________________
78 C-10 5.3 LSX -4L60E |
03-08-2010, 11:51 PM | #24 |
Senior Member
Join Date: May 2009
Location: Fort Worth, TX
Posts: 6,370
|
Re: OK I'm stumped..
[QUOTE=78-5.3 but you telling me to get under the truck disconnect the connector at the tank and see if it pegs out right?[/QUOTE]
Yes. This helps narrow down where problem is. Last edited by clinebarger; 03-08-2010 at 11:52 PM. |
03-09-2010, 01:21 AM | #25 |
resident wrencher
Join Date: Dec 2006
Location: ramona california
Posts: 720
|
Re: OK I'm stumped..
thanks tons cline but one question is the fuel tank slector and meeter valve under the bed with the lines connected to it?
|