The 1947 - Present Chevrolet & GMC Truck Message Board Network







Register or Log In To remove these advertisements.

Go Back   The 1947 - Present Chevrolet & GMC Truck Message Board Network > General Truck Forums > Suspension

Web 67-72chevytrucks.com


Reply
 
Thread Tools Display Modes
Old 11-19-2010, 09:35 AM   #1
bw4sale
Registered User
 
bw4sale's Avatar
 
Join Date: Sep 2006
Location: Hendersonville, TN
Posts: 1,528
Two tanks - one compressor

Can I run two 3 gallon tanks and only one compressor? I'm thinking of going this route so that I can put the tanks under the bed instead of in the bed. How would you plumb it? Just run a line between the two tanks to connect them with the compressor connected to one of them or split the line coming from the compressor and send a feed to both tanks?
__________________
BRENT



-'68 Stepside Project
-'98 Z71 Daily Driver
-Enough extra parts to build another truck and a half
bw4sale is offline   Reply With Quote
Old 11-19-2010, 10:05 AM   #2
N2TRUX
Happy to be here
 
N2TRUX's Avatar
 
Join Date: Mar 2000
Location: Cypress, TX
Posts: 39,021
Re: Two tanks - one compressor

It depends on how your bungs are arranged. On my 77 we have the inlet going in one end of the 1st tank and the outlet on the same end of the 2nd tank. The tanks are married on the other end.
Attached Images
  
__________________
Follow me on Facebook and Instagram @N2trux.com

Articles-

"Jake" the 84 to 74 crewcab

"Elwood" the77_Remix

85 GMC Sierra "Scarlett"

"Refining Sierra"
N2TRUX is offline   Reply With Quote
Old 11-19-2010, 10:14 AM   #3
bw4sale
Registered User
 
bw4sale's Avatar
 
Join Date: Sep 2006
Location: Hendersonville, TN
Posts: 1,528
Re: Two tanks - one compressor

My compressor will probably be mounted somewhere around where yours is, but my tanks will be outside the framerails on each side. I would rather send a feed to both tanks rather than tie them together, but didn't know if this would cause any issues.
__________________
BRENT



-'68 Stepside Project
-'98 Z71 Daily Driver
-Enough extra parts to build another truck and a half
bw4sale is offline   Reply With Quote
Old 11-19-2010, 01:20 PM   #4
jimmydean
Registered User
 
jimmydean's Avatar
 
Join Date: May 2005
Location: Beaverton, OR
Posts: 3,728
Re: Two tanks - one compressor

I would think you would want your feed line as short as possible, so it's best to tie the tanks together. You could still do the tanks outside, just mount the compressor near one of them, then run a line to the other.
__________________
New Project: 1966 LWB C20
Plans:
1/2 ton conversion
Dropmember front
Dropmember rear
Corvette discs
Restored raised bed

http://67-72chevytrucks.com/vboard/s....php?p=4295210
jimmydean is offline   Reply With Quote
Old 11-19-2010, 03:47 PM   #5
dznucks
Registered User
 
dznucks's Avatar
 
Join Date: Feb 2006
Location: Smyrna, Ga
Posts: 1,647
Re: Two tanks - one compressor

I am running two 3 gal tanks and a single compressor. i ran mine like n2trux describes, but my tanks are on either side of the frame rails, in front of the rear tires. Compressor is in back passenger corner tucked up under the bed.

What type of valve set up do you plan to run? seperate valves or valve block?

If you run a dual feed, your doubling you chances that something could happen to that feed line and take out your whole system. ie, road debris or something. I ran a single 3/8" hard line from the compressor to the first tank. then ran 1/2" hard line from tank to tank and then from the second tank to my accuair valve block. The larger 1/2" line allows more volume of air to be delivered.

One thing to remember about pressure is that the pressure in a system is equal everywhere in the system at all times. So your not gaining anything by using a dual feed, just adding risk.
dznucks is offline   Reply With Quote
Old 11-19-2010, 05:14 PM   #6
bw4sale
Registered User
 
bw4sale's Avatar
 
Join Date: Sep 2006
Location: Hendersonville, TN
Posts: 1,528
Re: Two tanks - one compressor

That makes sense about the risk. Hadn't even thought of that.

I'm going with the accuair VU4 block (don't have it yet). Here's what I was thinking. If I run a feed to each tank, then I can run a line from each tank to the block since it has 2 air inputs. I believe the 3 gal. tanks have just two ports plus a small port for a gauge. Do I gain anything by running two feeds to the block? The pressures the same but what about the volume?
__________________
BRENT



-'68 Stepside Project
-'98 Z71 Daily Driver
-Enough extra parts to build another truck and a half
bw4sale is offline   Reply With Quote
Old 11-21-2010, 03:46 PM   #7
bw4sale
Registered User
 
bw4sale's Avatar
 
Join Date: Sep 2006
Location: Hendersonville, TN
Posts: 1,528
Re: Two tanks - one compressor

Anyone else have any thoughts?
__________________
BRENT



-'68 Stepside Project
-'98 Z71 Daily Driver
-Enough extra parts to build another truck and a half
bw4sale is offline   Reply With Quote
Old 11-21-2010, 07:33 PM   #8
dznucks
Registered User
 
dznucks's Avatar
 
Join Date: Feb 2006
Location: Smyrna, Ga
Posts: 1,647
Re: Two tanks - one compressor

Yes you would gain from using both inlets on the accuair block.
The block used 3/8" ports. I ran a single 1/2" hard line to the block then split it into two 3/8 lines to feed both ports. Its lighting quick when you raise the truck.

in this link you can get the idea for how i ran my lines. i can get a good picture of whats inside the black box. both the valve and ecu are inside. i wanted to keep all of that stuff protected from debris and water.


http://67-72chevytrucks.com/vboard/s...d.php?t=399396
dznucks is offline   Reply With Quote
Old 11-21-2010, 08:01 PM   #9
mario1128
Registered User
 
Join Date: Jan 2009
Location: cheshire ct
Posts: 55
Re: Two tanks - one compressor

how about on the feedline to each tank have a checkvalve to only let air in in case the main line or other tank goes bad it wont empty both tanks.
__________________
72 chevy former 1ton converted to 1/2 ton roller 350 engine , turbo 350 and a 12 bolt on leafsprings with a flip and drop springs
mario1128 is offline   Reply With Quote
Old 11-21-2010, 08:19 PM   #10
dznucks
Registered User
 
dznucks's Avatar
 
Join Date: Feb 2006
Location: Smyrna, Ga
Posts: 1,647
Re: Two tanks - one compressor

Quote:
how about on the feedline to each tank have a checkvalve to only let air in in case the main line or other tank goes bad it wont empty both tanks.

very good point....i forgot to mention.

The Viair compressor has a check valve at the end of the pigtail. With the Accuair valve you will want to put a check valve between the second tank and the valve. when the pressure in the tanks drops below the pressure in the bags, the valve will back flow and the whole system will drain, bags and all.

Doing this will seal your air supply system in the event of compressor failure or valve malfunction. I designed my system with preventing failure in mind.

Last edited by dznucks; 11-22-2010 at 08:50 AM.
dznucks is offline   Reply With Quote
Old 11-21-2010, 11:27 PM   #11
bw4sale
Registered User
 
bw4sale's Avatar
 
Join Date: Sep 2006
Location: Hendersonville, TN
Posts: 1,528
Re: Two tanks - one compressor

Quote:
With the Accuair valve you will want to put a check valve between the second tank and the valve. when the pressure in the tanks drops below the pressure in the bags, the valve will bag flow and the whole system will drain, bags and all.
Good idea. Hadn't thought about that.
__________________
BRENT



-'68 Stepside Project
-'98 Z71 Daily Driver
-Enough extra parts to build another truck and a half
bw4sale is offline   Reply With Quote
Reply

Bookmarks


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump


All times are GMT -4. The time now is 11:29 PM.


Powered by vBulletin® Version 3.8.11
Copyright ©2000 - 2024, vBulletin Solutions Inc.
Copyright 1997-2022 67-72chevytrucks.com