LS Alt Charge Wire

I currently have my battery mounted under the bed behind the cab on the driver's side. I ran a 1/0 welding cable to a 300 amp marine grade breaker, 1/0 from breaker to the alternator charge terminal, 1/0 cable from charge terminal to starter solenoid. I see plenty of diagrams showing the alt wired between the battery and starter. Any issues with doing it as stated above? Seems fine and starts /charges perfectly (have started numerous times on the rolling chassis). Just didn't want to fry the alt post or something. Not a DC electric pro!

Voltage at all points reads darn near identical / not much voltage drop to speak of at all if any.

I will be running a separate 6AWG welding cable circuit from the battery that will have its own protection to a junction block for powering the ECM, main fuse panel inside, and other accessories. Each circuit off junction block will also be properly protected.
1bad396ss is offline   Reply With Quote
 

Bookmarks

Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump


All times are GMT -4. The time now is 12:35 AM.


Powered by vBulletin® Version 3.8.11
Copyright ©2000 - 2024, vBulletin Solutions Inc.
Copyright 1997-2022 67-72chevytrucks.com