Question HEI with Generator

I am running a 283 with standard distributor right now. I was given an HEI distributor to install. My question is, when I install the HEI should I convert the generator over to alternator? I have heard that the generator will not keep up the volts for the HEI.
a37lesalle is offline   Reply With Quote
Old 01-20-2013, 11:25 AM   #2
Wrenchbender Ret
Registered User
 
Join Date: Oct 2005
Location: Overland Park, Ks.
Posts: 5,229
Re: HEI with Generator

The HEI will work fine with the gen. If you are going to use the truck a lot & have added electric equipmwnt if would be preferable to change to alt.
Wrenchbender Ret is offline   Reply With Quote
Old 01-20-2013, 07:35 PM   #3
a37lesalle
Registered User
 
a37lesalle's Avatar
 
Join Date: Mar 2012
Location: Bakersfield calif
Posts: 40
Re: HEI with Generator

Quote:
Originally Posted by Wrenchbender Ret View Post
The HEI will work fine with the gen. If you are going to use the truck a lot & have added electric equipmwnt if would be preferable to change to alt.
Thank you for the info. I do not plan on a lot of electrical stuff but will keep the info in mind if I do.
a37lesalle is offline   Reply With Quote
Old 01-20-2013, 09:39 PM   #4
brokenspoke
Registered User
 
brokenspoke's Avatar
 
Join Date: Jul 2011
Location: Anderson, Texas
Posts: 535
Re: HEI with Generator

Just be sure and get a full 12 volts direct from fuse box....keyed.....not the old coil wire
brokenspoke is offline   Reply With Quote
Old 01-20-2013, 11:00 PM   #5
PoDuck
Registered User
 
Join Date: Dec 2012
Location: St. George, UT
Posts: 155
Re: HEI with Generator

I ran my '62 for years with generator/HEI with no problems. The generator light didn't come on any more often than before.
PoDuck is offline   Reply With Quote
Reply

Bookmarks


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump


All times are GMT -4. The time now is 02:02 PM.


Powered by vBulletin® Version 3.8.11
Copyright ©2000 - 2025, vBulletin Solutions Inc.
Copyright 1997-2022 67-72chevytrucks.com