HEI Wire Size?

I have read in various sources that I need to use anything from a #14 to #10 wire from the fuse block to the BAT terminal on my new HEI distributor.

Should I be concerned if I used #14?

Thanks!
avejoe is offline   Reply With Quote
Old 01-04-2004, 12:25 AM   #2
TODDS 72
Not the nightly winner
 
TODDS 72's Avatar
 
Join Date: Jul 2002
Location: CHARLEMONT MA.USA
Posts: 763
10 gage is what you want to use
__________________
72C10SWB BLUE 350/350
86K10LWB BLUE 5.7 700r4 7.5' fisher plow
93S10XCAB4X4 BLUE 4.3 4L60e
69gmc c10 v8 3 on the tree yellow 72k10 swb 350 3 on the tree green
86k15 swb5.0L 4spd brown
TODDS 72 is offline   Reply With Quote
Old 01-04-2004, 02:54 AM   #3
Hooter
My other Love
 
Hooter's Avatar
 
Join Date: Aug 2001
Location: Castlegar B.C. Canada
Posts: 4,085
14 is a bit on the thin side, factory used 12, I would recomend you wire it through a solenoid too
__________________




Castlegar B.C.The great white North (Canada Eh!)
Hooter_5@hotmail.com
First generation Monte Carlo club
pictures of my life
Hooter is offline   Reply With Quote
Old 01-04-2004, 05:50 AM   #4
Jerdog
Registered User
 
Join Date: Feb 2003
Location: Bakersfield, CA
Posts: 38
I think #14 AWG should be fine. You're only talking about a short run from the fuse panel to the distributer. Not very much voltage drop in seven feet of #14.
Jerdog is offline   Reply With Quote
Old 01-04-2004, 01:06 PM   #5
Rooster's 67
Registered User
 
Rooster's 67's Avatar
 
Join Date: Sep 2003
Location: DFW
Posts: 765
amperage draw of most HEI coils will run about 10 amps use #12 gauge wire at least.
__________________
The problem with America is stupidity. I'm not saying there should be a capital punishment for stupidity, but why don't we just take the safety labels off of everything and let the problem solve itself?
Rooster's 67 is offline   Reply With Quote
Old 01-04-2004, 01:23 PM   #6
junkyardjohn
Registered User
 
junkyardjohn's Avatar
 
Join Date: Aug 2001
Location: SOMERSET KY.
Posts: 6,425
Quote:
Originally posted by Hooter
14 is a bit on the thin side, factory used 12, I would recomend you wire it through a solenoid too
HOOTER -- WHY ON EARTH WOULD YOU PUT A SOLENOID INLINE BETWEEN YOUR FUSE BLOCK & DIST.????
__________________
junkyardjohn
69 1 TON TOW TRUCK //
84 4WD CUCV BLAZER// 85 1 TON 4WD STAKE TRUCK// 86 M1031 5/4 TON 4WD CUCV// ALOT OF OLD TRUCKS FOR ONE OLD MAN TO DRIVE. THERES ROOM FOR ALL OF GODS CREATURES RIGHT NEXT TO MY MASHED POTATOES//
LIFE MEMBER OF P.E.T.A (PEOPLE EATING TASTY ANIMALS)

DON'T RENT U-HAUL

ALWAYS TELL THE TRUTH
IT WILL AMAZE PART OF THE PEOPLE & ASTONISH THE REST
junkyardjohn is offline   Reply With Quote
Reply

Bookmarks


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump


All times are GMT -4. The time now is 04:51 AM.


Powered by vBulletin® Version 3.8.11
Copyright ©2000 - 2025, vBulletin Solutions Inc.
Copyright 1997-2022 67-72chevytrucks.com