The 1947 - Present Chevrolet & GMC Truck Message Board Network







Register or Log In To remove these advertisements.

Go Back   The 1947 - Present Chevrolet & GMC Truck Message Board Network > 47 - Current classic GM Trucks > The 1947 - 1959 Chevrolet & GMC Pickups Message Board

Web 67-72chevytrucks.com


Reply
 
Thread Tools Display Modes
Old 07-08-2015, 09:17 PM   #1
turnjare
Registered User
 
turnjare's Avatar
 
Join Date: Sep 2013
Location: Pocatello, Idaho
Posts: 29
Do I have the correct sending unit for my tank?

Hi Everyone,
I'm trying to decide if I have the correct sending unit. The truck is a 1949 with a frame mounted gas tank. The fuel gauge reads half full when the tank is empty. I thought it was because i am converted to 12V and that I needed a voltage reducer to continue using the old gauge, but now I think its something else. The travel on the sending unit is 13 inches and the depth of my bed mounted tank is only 8 inches. When I took out the sending unit and tested it, it read empty on the gauge when fully extended to 13 inches! great news, I don't need a voltage reducer. The bad news is that it seems that I need a sending unit with a shorter travel so I can use it in a 8 inch deep tank. Are those available, or should I try to modify (bend) the one I have? Does anyone have a pic of a sending unit being used in a under bed mounted tank?

Thanks

turnjare is offline   Reply With Quote
Old 07-08-2015, 11:05 PM   #2
mr48chev
Registered User
 
mr48chev's Avatar
 
Join Date: Jul 2007
Location: Toppenish, WA
Posts: 15,711
Re: Do I have the correct sending unit for my tank?

Why not modify the existing sending unit to work with the tank and read correctly?

You have too possibilities for correcting it and may have to use both.

1. The pivot point for the float arm needs to be at a depth in the tank that allows full float travel both to the bottom and the top to go from empty to full.

2. the length of the float arm needs to be correct to allow full float travel. A longer arm is going to reduce the total degrees of swing of the float while too short of an arm won't let the float go to the bottom or top of the tank or close enough to read correctly. On that If it were me I would want the float to end it's travel about a half inch from either the top or bottom of the tank.

Scroll down this page a bit and he did a drawing/demo using an actual float that shows pretty well how one should be set up to work right. I can't draw pictures that match what he has using the actual float. https://www.hotrodhotline.com/instal...r#.VZ3lk_kTprR
__________________
Founding member of the too many projects, too little time and money club.

My ongoing truck projects:
48 Chev 3100 that will run a 292 Six.
71 GMC 2500 that is getting a Cad 500 transplant.
77 C 30 dualie, 454, 4 speed with a 10 foot flatbed and hoist. It does the heavy work and hauls the projects around.
mr48chev is offline   Reply With Quote
Reply

Bookmarks


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump


All times are GMT -4. The time now is 10:11 AM.


Powered by vBulletin® Version 3.8.11
Copyright ©2000 - 2024, vBulletin Solutions Inc.
Copyright 1997-2022 67-72chevytrucks.com